It is top quality and the most cost effective product for your flat roof.
Insulation for flat roof regulations.
A qualified roofing contractor will be able to advise on this but here are some of the main guidelines.
A lower u value indicates better insulation properties hence u value requirements usually specify a maximum value.
At least 100mm of rigid board insulation must be positioned on top of the vapour control layer the vapour control layer stops any moisture within the building contaminating the insulation.
If moisture is a major concern you can also install xps rigid insulation which offers superior moisture resistance.
U value of a flat roof to comply with part l of the building regulations 2010 all roofs to rooms except those in unheated buildings should be thermally insulated to a maximum u value of of 0 18 w m k.
Building regulations for insulating a roof.
One of the main benefits you will receive from installing a warm flat roof is condensation will not become an issue because of the positioning of the insulation.
Cold deck the thickness of insulation required will vary depending on the material you decide to use and the manufacturer s specification.
While expensive the best insulation is polyiso rigid foam.
The limiting u value the maximise u value which cannot be exceeded required under current building regulations for the roof is 0 20w m.
Building regulations standards set the levels of thermal insulation required when carrying out building work either for new build or refurbishment projects.
You can expect to pay about 55 100 sq ft.
Insulation entirely above the roof deck directly below the roof deck or both above and below the roof deck.
For a 1 inch board equivalent of 6 r value.
There must be a slope of 1 80 part h of the building regulations regarding drainage state that water should drain to one or two edges waterproofing should extend up the adjacent walls at least.
Insulation on the floor of the attic figure 1.
Insulation tight to the roof deck i e.
Heat rises and therefore the building regulations requirements for heat loss through roofs are more stringent than those for walls.
Continuous insulation zones ashrae 90 1 ashrae 189 1 igcc ibc iecc 2004 2007 2010 2013 2016 2009 2011 2014 2012 2015 2009 2012 2015 0 25 1 15 20 2 15 20 25 3 15 20 25 4 15 20 302535 5 15 20 302535 6 15 20 3035 7 15 20 3540 25 8 20 3540 25 minimum r value non residential above roof deck.
The required u value will depend on the location of the project england scotland or wales type of building domestic or non domestic and the application floor wall or roof.
Possible locations for insulation within the roof assembly as addressed by ibc include.